Features - Thermal cut-off and auto reset function for protection against misuse and overloading - Fire rated to 60/60/60 minutes - 3 mounting clips to ensure optimum snug fit to ceiling
Test Specifications - Tested by BRANZ in accordance with AS1530.4.1997; test report No. FP2971 and FAR1792. - Suitable for floor-ceiling systems Gib_ specification No's GBFC15; GBUC15; GBFC30; GBTP30; GBSC30; GBUC30a; GBUC30b; GBSC60; GBFC60; GBTP60 and GBUC60.
60/60/60 Minutes Approval - a) 60 Minutes Stability: To prevent collapse of structural (primary) elements during fire. - b) 60 Minutes Integrity: To prevent passage of flame or hot gases through fire separations. - c) 60 Minutes Insulation: To prevent the transmission of heat to other firecells or adjacent property.
(RW)STC Sound Transmission Class - Acoustic ratings STC 55; 57 and 58 - For acoustic STC 55 ceilings; space 1.6m minimum - For acoustic STC 57 and 58 ceilings; space 2.5m minimum
Installation Notes - For use in 60 minutes floor ceiling systems (also usable for 15 minutes and 30 minutes) - Only install one fitting in each unsupported section of ceiling lining between timber framing - Cut 125mm hole not closer than 50mm to timber - Apply bead of SD-MASTIC to flange so as to fill hole gap
Product Certification Warning - BRANZ Fire Tests FP2208; FP2918; FP2998 and FP2971 were conducted exclusively with Superlux manufactured product.
Specifications - Input Voltage: 240V - Lamp Type: E27 - Energy efficient: Energy saving LED ready - Class: CA90 - Air / Moisture Transfer: Closed - Insulation: Side Abutted